Box Module
SP-5B00 Series |
SP-5B00 |
SP-5B10 |
SP-5B90 |
SP-5B40, SP-5B41, SP-5B411, SP-5B412 |
|
---|---|---|---|---|---|
Display Unit |
|
||||
Screen Area (Unit: byte) |
64M |
64M |
64M |
64M |
|
Portrait Installation |
|
|
|
|
|
Function Expansion Memory |
- |
- |
- |
- |
5.4.7 System Settings [Display Unit] - [Extended] Settings Guide |
Installing the USB/RS-422/485 Conversion Adapters |
|
|
|
- |
|
MAC Address Display |
|
|
|
|
|
External Storage |
|
||||
CF Card |
- |
- |
- |
- |
|
SD Card |
|
|
|
|
|
CFast Card |
- |
- |
- |
|
|
USB storage |
|
|
|
|
|
FTP server |
|
|
|
- |
|
System Settings |
|
||||
Drawing in 256 colors |
|
|
|
|
|
Reverse Display |
- |
- |
- |
- |
5.4.2 System Settings [Display Unit] - [Display] Settings Guide |
Faded Color Blink |
- |
|
|
|
5.4.2 System Settings [Display Unit] - [Display] Settings Guide |
Synchronize Text Display with Text Table |
|
|
|
|
5.4.2 System Settings [Display Unit] - [Display] Settings Guide |
Time Zone Settings |
|
|
|
5.4.2 System Settings [Display Unit] - [Display] Settings Guide |
|
Detect Backlight Burnout |
- |
- |
- |
- |
5.4.3 System Settings [Display Unit] - [Operation] Settings Guide |
Dimmer settings |
- |
||||
2 point touch / Multitouch |
2 points*4 |
2 points*4 |
- |
2 points*4 |
5.4.3 System Settings [Display Unit] - [Operation] Settings Guide |
Display the SD/USB Removal Icon |
|
|
|
- |
|
Screen Capture |
|
|
|
|
|
SRAM Auto Backup |
|
|
|
|
|
Image Font |
|
|
|
|
|
Bitmap Font |
|
|
|
|
|
Standard Font |
|
|
|
|
5.4.7 System Settings [Display Unit] - [Extended] Settings Guide |
Port Control |
|
|
|
5.4.10 System Settings [Display Unit] - [Port Control] Settings Guide |
|
Device/PLC Communication*2 |
|
||||
Number of Device/PLC drivers that can communicate simultaneously |
4 |
4 |
4 |
4 |
|
Specify Indirect Device |
|
|
|
|
|
Import Device/PLC tags |
|
|
|
|
|
Ethernet Multilink |
|
|
|
|
7.6 Connecting Multiple Display Units to One Device/PLC (Ethernet Multilink) |
Device Monitor |
|
|
|
|
42.5 Monitoring the Value of Device Addresses (Device Monitor) |
Ladder Monitor |
- |
- |
- |
- |
"PLC Ladder Monitor Operation Manual" |
Transfer |
|
||||
Network Transfer |
|
||||
Modem Transfer |
|
|
|
- |
|
SIO Transfer (COM Connection) |
|
|
|
- |
|
Memory loader feature |
|
|
|
|
34.8 Transferring Project Files Using a CF Card or USB Storage |
CF/SD Card Connection |
|
|
|
|
|
Connection Key |
|
|
|
|
|
Common Settings |
|
||||
Change Backlight Color |
- |
- |
- |
- |
|
Clock Update Settings |
|
|
|
- |
|
Start Screen Settings |
|
|
|
- |
|
Date format on CSV file output |
|
|
|
|
|
Divide destination folders by file numbers |
|
|
|
|
|
Increase Alarm Type [Extended] settings and Text Table index numbers |
|
|
|
|
|
Alarm Message Multiple Line Display |
|
|
|
|
|
Attach Data Value to Operation Log |
|
|
|
|
|
Changing passwords at run time (CSV file) |
|
|
|
|
|
Changing passwords at run time (password change screen) |
|
|
|
|
|
Append Date/Time to CSV File Name |
|
|
|
|
|
Transfer sampling CSV file to FTP |
|
|
|
- |
|
Transferring Sampled Data to the Cloud |
|
|
|
|
|
Indirectly specify Sampling Frequency and Alarm Settings |
|
|
|
|
|
Sampling data/Enhanced recipe data format co-exist |
|
|
|
|
|
Create a recipe (CSV data) index file at runtime |
|
|
|
|
|
Enhanced Recipes |
|
|
|
|
|
Extended Script copy file function |
|
|
|
|
|
Global Trigger |
|
|
|
|
|
Movie record/play feature |
- |
- |
- |
- |
|
Use image unit |
- |
- |
- |
- |
28.6 Displaying Multiple Video Camera Outputs Simultaneously |
Sound Output Feature |
- |
|
|
|
|
AUX |
- |
|
|
|
|
Retentive Variables Function |
|
|
|
|
|
Parts |
|
||||
Selector List |
|
|
|
|
|
XY Graph |
|
|
|
|
19.9 Displaying Sampled Data in a Scatter Graph 19.11 Displaying Current Values of Multiple Addresses All at Once in a Scatter Graph |
Picture Display [Image Display] for showing JPEG file |
|
|
|
|
|
Indirectly specify a block of Alarm parts |
|
|
|
|
|
Special Data Display [File Manager] sort function and default path |
|
|
|
|
|
Special Data Display Part [File Manager] copy file to FTP |
|
|
|
- |
|
Message Display's Bulletin Message |
|
|
|
|
17.5 Displaying the Same Message on Multiple Display Units (Bulletin Messages) |
Image Sensor Display |
|
|
|
|
|
Animation |
|
|
|
|
|
Alarm History Message Flow Display |
|
|
|
|
|
Alarm History/Sampling Data/Enhanced Recipe Data Refine Search/Sort Function |
|
|
|
|
20.10 Searching / Sorting Alarm History |
Alarm Analysis Function |
|
|
|
|
|
Logic |
|
||||
Logic Program Operation |
|
|
|
- |
|
I/O Driver |
- |
- |
|||
Function Block |
|
|
|
- |
|
Network |
|
||||
RPA Function |
- |
- |
- |
- |
|
GP-Viewer EX |
|
|
|
|
|
Web Server |
-*12 |
-*12 |
-*12 |
- |
|
Camera-Viewer EX |
- |
- |
- |
- |
|
Pro-face Remote HMI |
|
|
|
||
|
|
|
|
|
|
GP Remote Printer Server |
|
|
|
- |
|
Pro-face Connect (Models you can register as SiteManager) |
|||||
DHCP Function |
|
|
|
- |
|
Input Equipment/Peripheral Equipment (USB Device) |
|
||||
USB Keyboard |
|
|
|
|
|
EZ Illuminated Switch |
|
|
|
|
|
EZ Tower Light |
|
|
|
|
Cockpit parts are listed on our support site*3 |
EZ Numpad |
|
|
|
|
|
EZ Fingerprint Recognition Unit |
|
|
|
|
|
EZ LAN Adapter |
- |
- |
- |
- |
*1 While dimmed, brightness settings you can use are 0 to 100.
*2 Depends on the type of connected PLC/Device.
*3 http://www.pro-face.com/trans/en/manual/1001.html
*4 Available only when connected to the Premium Display.
*5 You cannot configure the Time Zone settings in offline mode.
*6 You can also use the "Pro-face Remote HMI Server".
*7 Run forced transfer on LAN1 (Ethernet1 port).
*8 Define SiteManager settings in offline mode.
M.17.2.9 Main Unit - Remote Viewer Settings
*9 Set up SiteManager in a browser. For more information, refer to the "Pro-face Connect GateManager User Manual".
http://www.pro-face.com/trans/en/manual/1001.html
*10 Available only when connected to the Fieldbus master unit. For details, see the Fieldbus Master Unit Hardware Manual.
*11 Port control for SiteManager Embedded (Pro-face Connect) is not supported.
*12 Supported in V4.09.450 or earlier.
Display Module
|
SP-5400WA, SP-5500WA, SP-5600WA, SP-5600TA |
SP-5500TP, SP-5600TP, SP-5660TP, SP-5700TP |
SP-5700WC, SP-5800WC |
SP-5490WA, SP-5690WA, SP-5790W |
|
---|---|---|---|---|---|
2 point touch / Multitouch |
- |
2 points |
2 points |
- |
5.4.3 System Settings [Display Unit] - [Operation] Settings Guide |
Brightness sensor |
- |
|
|
- |
M.2.3 Adjusting the Display Brightness Automatically Based on Ambient Brightness |
Front USB |
- |
|
|
- |