38.3.4.2 When Using the Same Computer for Running WinGP

  1. To start WinGP, either double-click the shortcut on the desktop, or from the [Start] menu, click [WinGP] - [WinGP].

  2. Switches to offline mode.

    • When the [Welcome] screen is displayed, click [Transfer Memory Loader].

    • If you are using WinGP that was not installed in the Program files folder, skip to step 5 without switching to offline mode.

  3. In offline mode, click [Transfer]-[Transfer Project File].

  4. In the dialog box that displays, touch [Yes] to start WinGP. WinGP started with administrator rights displays in a separate window.

  5. On the GP-Pro EX state toolbar, click [Transfer Screen] to launch the transfer tool.

  6. Confirm the project details in [Project Information]. To transfer a different project file, click the [Select Project] button and select the project file.

  7. Click [Transfer Settings].
    In [Communication Port Settings], select the [LAN] option. Clear the [Automatic] check box and click [OK].

  8. Click [Send a Project]. The [Select Display Unit] dialog box appears.

  9. Click [Add], enter [127.0.0.1] in the [IP Address] field, and click [OK].

    • The IP address [127.0.0.1] is a virtual address that indicates the computer you are currently using on the network.
      If the IP address [127.0.0.1] cannot be used, please use the IP address of the computer you are working on.

    • Make sure that the [Port] number matches the port number specified in the System Settings [Display Unit], [WinGP Settings] tab, [Transfer Settings] area.

  10. Select the [127.0.0.1] check box displayed in [IP Address] and click [OK].

  11. When the following dialog box appears, click [Yes]. (The dialog box will not appear if you transfer the same project again.)

    To transfer the project file, you can also use [ProjectCopy] (copy tool). For information on the setup procedure, see the following.
    38.3.4.1 When Using a Different Computer for Running WinGP, section title “Transfer using external storage”
    After transfer is completed, WinGP is restarted if it was started with user rights. WinGP exits if it was started with administrator rights.