30.13.1 Starting the Logic Monitor

There are 3 ways to start the logic monitor.

Logic monitoring begins when you turn on the first bit of the #L system variable (#L_LogicMonitor) using a switch part.
Turn off the first bit to display the screen before logic monitoring begins. Specify #L_LogicMonitor.X[1] for the address. The #L_LogicMonitor.X[0] is for monitoring addresses. The address monitoring screen appears when the system variable specification bit is turned on, such as during logic monitoring.

Using an instruction, turn on bits 0 (Address Monitor) and 1 (Logic Monitor) of #L system Variable (#L_LogicMonitor).

On the system menu, touch [Logic Monitor] and [Address Monitor].