30.14.10.1 CSV File Format

In the [Edit Symbol Variables] window, click [Utility] and then click [Export] to output information on the symbol variable settings as a CSV-format file as follows.

Header Information

The GP-Pro EX header information is attached to the exported CSV file. If any changes are made to the information, an error will occur during import. Please do not edit the information.

(Please do not edit.)

SymbolVariable (Please do not edit.)

The file version is saved. (Please do not edit.)

Symbol Variable Information (Required)

This is information on the symbol variables.

Stores the symbol variable name. To specify the array, use the "@" character for the array size starting from the next row.

When specifying the array, use sequential values starting from zero as the index.

Input the symbol variable type using the following text.

Type

Text

Bit Address

BitAddress

Word Address

WordAddress

Bit Variable

BitVariable

Integer Variable

IntegerVariable

Float Variable

FloatVariable

Real Variable

RealVariable

Timer Variable

TimerVariable

Counter Variable

CounterVariable

Time Variable

DateVariable

Date Variable

TimeVariable

PID Variable

PidVariable

Input the address category using the following text.

Category

Text

Text

Remarks

Internal Address

LS Area

#INTERNAL

You can use it only with direct access.

USR Area

#INTERNAL

 

Memory Link System Area

#MEMLINK

You can use it only with memory link.

External Address

PLC1-4

You can use it only with direct access.

Input the address value.

Input the retentive/volatile settings.

Settings

Value

Retentive

1

Volatile

0

Type any comments.