******************************* GP-Pro EX V2.6 ******************************* July 2010 Digital Electronics Corp. [Fixed Defects] = V2.60.300 ==================================================================== 1. Editor (Editor) - When the logic screen is monitored in the project where the specific Device/PLC (*1: Device/PLC where customers can register the tags variables) is set, "?" may be displayed for a symbol name. - Once a bar code is specified in the project where the specific Device/PLC (*1: Device/PLC where customers can register the tags/variables) is set, a warning is displayed during the error check even when the bar code settings are disabled in the subsequent processes. (*1) Manufacturer: OMRON Corporation Series: CS/CJ Series EtherNet/IP Manufacturer: Rockwell Automation, Inc. Series: EtherNet/IP Manufacturer: Fuji Electric FA Components & Systems Co., Ltd. Series: MICREX-SX Series SIO Manufacturer: Fuji Electric FA Components & Systems Co., Ltd. Series: MICREX-SX Series Ethernet 2. Display Unit (Runtime) - When you switch the screen to the one where Visibility Animation has been specified for the grouped parts, touch may be enabled even in an invisible state. - Base Screen where a mark screen has been placed is specified in Picture Display. When a switch is touched while the "Picture Display" screen is changed, the reverse display position of the switch may be shifted. = V2.60.200 ==================================================================== 1. Display Unit (Runtime) - In Most Recent Time, Oldest Time and Selected Time, the sampling time "00:00:00" is displayed as "**:**:**". - When an index file is used in Condition Name Search Feature of Transfer CSV Data, no search may be made. - When a barcode reader of the USB connection is removed, 5V power of COM1 may not be supplied. - When "Change Keypad" and "Input Mode Change" switches are overlapped, neither of them is operated. - When "0xFFFF" is written in the Screen Display ON/OFF address using "Word Switch", the screen may be displayed soon after it turns off for a moment. - When "#H_CurrentDayofTheWeek" is used, "7" that is outside of the valid range may be displayed. - When Counter Instructions are zoomed in Logic Monitor, nonexistent characters are displayed. In addition, the instruction name is not displayed in a part of the program control instructions (EXIT, PBC and PBR). - When the not-supported settings are made in "Printer Settings" and the system is rebooted, the system error occurs. - When the settings changed in the offline mode are saved in GP-4100 series, the communication speed in Script Settings is changed to [2400]. - Expansion memory (GP3000-EXDM01) may not be recognized. - When Simulation is executed by connecting with GX Simulator (from Mitsubishi Electric Corporation), the application error may occur. - The startup conditions for Cycle may not be established. (I/O Driver) - The specified synchronize output may not be turned on rare cases even when Synchronize Output in High Speed Counter is set in the I/O driver settings. (OS Core) - In AGP37**, AGP36**, AGP35**, AGP34** series, AGP3310T and AGP3360T: Even when the same IP address as the one of other equipment in the network is set to an AGP and later the AGP is connected to the nettwork, no error occurs. 2. Device/PLC - When data is written to "S54" (Specified frequency writing [RAM and EEPROM]) under the following conditions, the communication error (protocol error) may occur. Conditions: - The value of "P37" (rotation speed display) is "0". - The value of "S58" (link parameter expansion setting) is "1". - When a 17 or later bit device is specified for Alarm Summary in MEMOCON GL and MEMOCON SC series, it is not displayed normally. - Calculation in the character-to-character time-out has an error: Even when the communication idle time for 5 characters is made, it is processed as 1 packet. - When communication is made with the PLC, the communication error may occur on about a 49.71-day cycle in the continuous operation. - When Screen Change is executed with the serial multi-link used, a token may not be passed to another node. - When Screen Change is executed with the serial multi-link used, a token may not be passed to another node. - When Screen Change is executed with the serial multi-link used, a token may not be passed to another node. - When Screen Change is executed with the serial multi-link used, a token may not be passed to another node. - When a motion CPU is accessed, the "Address out of range" error may occur although the address is within the specified PLC range. - When continuous writing is made in the unit of bit using Pro-Server EX, the "Address out of range" error may occur although the address is within the specified PLC range. - When continuous writing is made in the unit of bit using Pro-Server EX, the values later than those for the 2nd bits may not be reflected to the PLC. 3. WinGP When "COM" is specified for "Port" in "Device/PLC", an application error may occur. = V2.60.100 ==================================================================== 1. Editor (Editor) - Editor may be abnormally terminated (ABEND) when the device/PLC is changed in Change Device/PLC in the case where Animation is specified on the D-script setup screen. 2. Display Unit (Runtime) - When Clear All Recovered Alarms is performed under the condition that Log is specified for Change Display Mode in Alarm History, the Trigger and Acknowledged records are not cleared. Similarly, when Clear All Acknowledged Alarms is performed in the same condition as above, the Trigger and Recovery records are not cleared. - When XON/XOFF is specified for Flow Control in the Device/PLC settings, the XON control code may become invalid in rare cases. (I/O Driver) - Even when "Current (4-20mA)" is specified for Data Type in EXM-AMO1HT, "Voltage (0-10V)" is displayed. 3. Device/PLC - MODBUS Slave driver may return no response when the baud rate is 115.2K. - Data cannot be read from Timer and Counter devices. ================================================================================ Warning: No part of this document may be used or reproduced without permission. **************************** End of Release Note *****************************