Products
Download
Contact us
Back to Top
 PL Series
 > PL-SM900 Software Mirroring Utility Update Module (for PL-X920/PS-2000B Series)

Please acknowledge the following terms of use before you use our download service. Download of any file signifies your agreement to the terms of use.

Terms of Use
  1. Schneider Electric Japan Holdings Ltd. ("SEJH") shall retain all intellectual property rights to the files that SEJH provides for this service.
  2. Who, uses or plans to use SEJH's products, may download and use any file.
  3. Reproduction, disclosure, re-publication, assignment, lease, decompilation, modification, falsification or reuse of any file that SEJH provides for this service shall be prohibited.
    However, for manuals, samples, BMP images and CAD files, you may reprint, duplicate, quote a part of the content or the whole on your company's specification sheets, or instruction manuals for built-in products. Also you may change the layout of the content.
  4. This download service is provided through the Internet. Please acknowledge that SEJH provides no guarantee of the condition at the time of provision, the availability of access and the condition of use concerning this service before you use this service.
  5. Please use this service at your own risk.
  6. If any additional conditions such as service usage conditions are attached to the downloaded files, please comply with such conditions as well.
Notices:
  1. Files are subject to deletion, or modification of the contents or specifications without notice.
  2. Please confirm that the downloading file size completely accords with the download file size shown.
  3. If the file sizes do not match, delete the file without decompressing and then download the same file once again.
 Download
File Name SM900Update_PL-X920_05.exe
SM900Update_PS-2000B_05.exe
File Size SM900Update_PL-X920_05.exe:1,613KB
SM900Update_PS-2000B_05.exe: 1,591KB
Correspondence series SM900Update_PL-X920_05.exe: PL-X920 Series
SM900Update_PS-2000B_05.exe: PS-2000B
Correspondence OS Windows NT®4.0, Windows®2000
Description
Update of PL-SM900 for the following version users.
- PL-SM900 Rev.Nothing
- PL-SM900 Rev.A
- PL-SM900 Rev.B
- PL-Sm900 Rev.C
Update Description
1. The following setting were added:
- Support for watching SMART by System Monitor.
- SoftMirror Log Viewer tool is added.
- Display Active Disk(disks in use) in System Monitor.
- An error pop up message by System Monitoris displayed again.

2. Restrictions
- The version of MSGINA.DLL will be set to 5.0.2195.4733 if Windows®2000 SP3 is installed. An error message is displayed at the time of Windows starting, and it becomes impossible to start.
This condition is avoidable with Windows®2000 SP4, or installation of Windows®2000 security update (KB824141).
- In the device manager of Windows®2000, "!" is displayed on "Digital SoftMirror IDE Driver".
It does not have influence on operation.
- If Windows®2000 is started with an USB device connected, it may result in a blue screen.
When you use an USB device, please connect after Windows®2000 has started up.
- When the hard disk changes to other one which rebuilt with other computers in mirror status "Good", mirror status may be set to "Good". Please do not use the hard disk which rebuilt with other computers.
- With too much vibration or heat, when it becomes impossible to use one hard disk while in use, it becomes impossible to also use another hard disk, and OS may freeze. Moreover, even if it switches on a power supply in the state, a hard disk cannot be recognized and OS may be unable to be started.
In this case, after removing an external factor, it is necessary to reboot.
- Not support for audio CD. Do not insert audio CD in CD-ROM drive.
- When the file system changed by the convert command, information of Mirror Status might be lost, and Mirror Status return to "Unconfig". In this case, it is possible to use it by executing "Config Mirror" and "Rebuild" again.

3. With this update, file versions changes as follows.
- Utility file
C:\Proface\Sysmon\smmon.exe --> 1.04
- Driver file
C:\WINNT\System32\drivers\smide.sys
--> Rev1.07
Manual PDF(634KB)

Extracting (Opening) the file (These are self-extracting files.)
1. Click "SM900Update_PL-X920_05.exe" if you use PL-X920 Series,
or click "SM900Update_PS-2000B_05.exe" if you use PS-2000B to download to your desired folder on your PC.

* If the update module cannot be downloaded to the PL, please download temporarily to the another PC, and copy the module to the PL unit where you want to install the module.

2. If the SoftMirror utility (smmon.exe) or System Monitor (PL_Smon.exe, PSB_Smon.exe) is open, please close it.
3. After the download is finished, double-click on the file to open it.
4. Update is performed automatically.
5. Please reboot after installation is complete.

Notes

- This update is only for PL-X920/PS-2000B Series.
Please do not use it for PL-5900 Series.
- In order to use this update, the old version of the Software Mirroring Utility must be installed.
* Version information can be confirmed via the [File | Properties] menu.

-

When using PL-SM900 on Windows®2000, Windows will not start up due to the installation of Windows®2000 SP3 or higher.
Please update PL-SM900 prior to the installaiton of service pack.

-

Setup to stop HDD
  To extend the operating life of the hard disk, Pro-face recommend you use one of the following procedures to turn the hard disk off when the unit is not being operated.
Pro-face recommands a setting of [After 5 min].
 
- When running Windows®2000
  Set the Windows [Control Panel]-[Power Options]-[Power Schemes] tab's [Turn off hard disks:] selection.
- When running Windows NT®
 
1. Click on the [Start] -> [Program] -> [System Monitor] -> [System Monitor Property] selections.
2. Set the [System Monitor Property] menu [Mirror] tab's [Turn off Hard Disk] selection.
3. Click [OK] to finish Setting.
4. Make short cut to [System Monitor] in [Start] -> [Program] -> [Startup].
(System Monitor stops hard disks, since Windows NT® does not have a function of hard disk stop.)

-

When System Monitor is already registered into start-up, the error message
"System monitor has started. Terminate the system monitor in Starting"
is displayed at the time of OS starting.
In this case, please delete the registered shortcut in start-up.

Update history
The history of correction
2004/09/22 - A newly placed HDD is recognized as GOOD once Mirror Status is GOOD.
  - BIOS is changes when an error occurs in master HDD during Rebuild.
2004/04/28 - The OS does not work if that there was no response from the HD when writing and reading data.
  - Event viewer could attribute error to incorrect disk.
  - Mirror Status is not changed even if a Soft Mirror error occurs at the time of Rebuild.
  - Even if Mirror Status was set to "Dead", "Good" may be displayed when Windows is rebooted.
(However, if it becomes impossible to write to both HDDs used with Soft Mirror, error information is not saved, and Mirror Status will be set to "Good" when Windows is rebooted.)
  - When using PL-X920 with Windows NT®, a check disk could start during reboot if Mirror Status was other than "Good".
The history of addition
2004/12/28 - In the case of Windows NT®, set up HDD stop time in 5 minutes.
  - Register System Monitor into start-up, and set up so that it may start automatically.
  - The Mirror surveillance by System Monitor is enabled.
2004/09/22 - Support function of HDD stop.
2004/04/28 - Support for SP3 and SP4 of Windows®2000.
  - The functional addition was made so that all changes of Mirror Status can be recorded on the event viewer.
(However, all classifications of an event log are displayed as error.)

Last Updated: May 16, 2005

| Return to Top | | Back | HOME |
FAQ for use | Protection of Personal Information | Trademark Acknowledgments | About Intellectual Property Rights | Terms of Use
Copyright (C) 2005- Schneider Electric Japan Holdings Ltd. All Rights Reserved.