 |
| PL
Series |
|
Please acknowledge the following terms of use before you use our download service. Download of any file signifies your agreement to the terms of use.
Terms of Use
- Schneider Electric Japan Holdings Ltd. ("SEJH") shall retain all intellectual property rights to the files that SEJH provides for this service.
- Who, uses or plans to use SEJH's products, may download and use any file.
- Reproduction, disclosure, re-publication, assignment, lease, decompilation, modification, falsification or reuse of any file that SEJH provides for this service shall be prohibited.
However, for manuals, samples, BMP images and CAD files, you may reprint, duplicate, quote a part of the content or the whole on your company's specification sheets, or instruction manuals for built-in products. Also you may change the layout of the content.
- This download service is provided through the Internet. Please acknowledge that SEJH provides no guarantee of the condition at the time of provision, the availability of access and the condition of use concerning this service before you use this service.
- Please use this service at your own risk.
- If any additional conditions such as service usage conditions are attached to the downloaded files, please comply with such conditions as well.
Notices:
- Files are subject to deletion, or modification of the contents or specifications without notice.
- Please confirm that the downloading file size completely accords
with the download file size shown.
- If the file sizes do not match, delete the file without decompressing and then download the same file once again.
|
| Confirm the following software applications are installed
on your hard drive. |
Installation(in GP-PRO/PB III C-Package01) --> GP-PRO/PBIII
C-Package01
Installation(in Pro-Control Editor) --> Pro-Control Editor
Installation(in LogiTouch Editor) --> LogiTouch Editor |
Please click on the software download filename that corresponds to
your installed software. |
Installation(in GP-PRO/PB III C-Package01) --> CF_64PS.exe
Installation(in Pro-Control Editor) --> PF_64PS.exe
Installation(in LogiTouch Editor) --> LF_64PS.exe |
| |
| Title |
Flex Network
Driver
(Single-axis Positioning Unit, 32-Point Input/Output
Units) |
| File
Name |
CF_64PS.exe
PF_64PS.exe
LF_64PS.exe |
| File
Size |
2,009 KB
(CF_64PS.exe)
2,061 KB (PF_64PS.exe)
1,888 KB (LF_64PS.exe) |
| Description |
Flex Network
Driver --> Update
Description |
| Version |
|
- |
Editor
: Ver. 1.50 |
| - |
GLC100
Series : Ver. 1.35 |
| - |
GLC300
Series : Ver. 1.35 |
| - |
GLC2300
Series : Ver. 1.12 |
| - |
GLC2400
Series : Ver. 1.32 |
| - |
GLC2600
Series : Ver. 1.32 |
| - |
LogiTouch
Series : Ver. 1.32 |
|
Compatible
Main Units |
|
GLC Series
Units : |
| - |
GLC100
Series : GLC100-SC41-24V, GLC100-LG41-24V |
| - |
GLC300
Series : GLC300-TC41-24V |
| - |
GLC2300
Series : GLC2300-TC41-24V, GLC2300-LG41-24V |
| - |
GLC2400
Series : GLC2400-TC41-24V |
| - |
GLC2600
Series : GLC2600-TC41-24V |
| LogiTouch
Series Units : |
| - |
LogiTouch
Type B+ : GLC150-BG41-XY32KF-24V  |
| - |
LogiTouch
Type B : GLC150-BG41-FLEX-24V |
| - |
LogiTouch
Type C : GLC150-BG41-RSFL-24V |
|
Compatible
Editor Software |
|
GP-PRO/PBIII
C-Package01 : GPPRO-CNT01W-P01 |
Pro-Control
Editor :
GLCCNT-ED01J-V10, GLCCNT-ED01J-V15
GLCCNT-ED01E-V15, GLCCNT-ED01J-V20
GLCCNT-ED01E-V20, GLCCNT-ED01W-V30 |
| LogiTouch
Editor : GLCLT-ED01J-V10, GLCLT-ED01W-V10 |
|
Compatible
Flex Network
I/O Units |
|
- |
Single-axis
Positioning : FN-PC10SK41  |
|
- |
High-speed
Counter : FN-HC10SK41 |
| - |
16-Point
Input Sink/Source : FN-X16TS41, FN-X16TS11 |
| - |
8-Point
Input Sink/Source, 8-Point Transistor
Output Sink :
FN-XY08TS41 |
| - |
8-Point
Relay Output/1 Common : FN-Y08RL41 |
| - |
16-Point
Output Sink : FN-Y16SK41 |
| - |
16-Point
Output Source : FN-Y16SC41 |
| - |
4 Channel
Analog/Digital Conversion : FN-AD04AH11 |
| - |
4 Channel
Digital/Analog Conversion : FN-DA04AH11 |
| - |
32-Point
Input Sink/Source : FN-X32TS41* |
| - |
16-Point
Input Sink/Source, 16-Point Transistor
Output Sink :
FN-XY16SK41* |
| - |
16-Point
Input Sink/Source, 16-Point Transistor
Output Source :
FN-XY16SC41* |
| - |
32-Point
Input Sink/Source, 32-Point Transistor
Output Sink :
FN-XY32SKS41*  |
| - |
32-Point
Input Sink/Source, 32-Point Transistor
Output Source :
FN-XY32SCS41(Due soon)* |
|
* GLC100
and GLC300 series units do not support
FN-X32TS41, FN-XY16SK41 and FN-XY16SC41
units. |
|
|
Prior to Installation |
| Prior to installing the Flex Network Driver, close
all your personal computer applications, including any resident program
such as a virus detection program, etc. |
Installation |
| 1. |
Click on the above File Name
to download data to the folder you wish to
use. |
| 2. |
After the download is finished,
double-click on the file to open it. |
| 3. |
Click on the [OK] button or
press the [Enter] key. When the message window
appears, click on [NEXT]. The [Setup Type]
window will then appear. |
| 4. |
Follow the installation
instructions as they appear on the screen. |
|
| |
| Important: |
| *1 |
When installing this software on
a PC using WindowsNT(R) , Windows(R)2000
or Windows(R)XP, you need to have administrator level
access rights. |
| *2 |
When reinstalling the editor, please install these drivers again. |
|
| Last Updated: June.18.2002 |
|