>PLCs >Mitsubishi Electric Corporation Q/QnA Series Serial Communication Driver
Please acknowledge the following terms of use before you use our download service. Download of any file signifies your agreement to the terms of use.
Terms of Use
Schneider Electric Japan Holdings Ltd. ("SEJH") shall retain all intellectual property rights to the files that SEJH provides for this service.
Who, uses or plans to use SEJH's products, may download and use any file.
Reproduction, disclosure, re-publication, assignment, lease, decompilation, modification, falsification or reuse of any file that SEJH provides for this service shall be prohibited.
However, for manuals, samples, BMP images and CAD files, you may reprint, duplicate, quote a part of the content or the whole on your company's specification sheets, or instruction manuals for built-in products. Also you may change the layout of the content.
This download service is provided through the Internet. Please acknowledge that SEJH provides no guarantee of the condition at the time of provision, the availability of access and the condition of use concerning this service before you use this service.
Please use this service at your own risk.
If any additional conditions such as service usage conditions are attached to the downloaded files, please comply with such conditions as well.
Notices:
Files are subject to deletion, or modification of the contents or specifications without notice.
Please confirm that the downloading file size completely accords
with the download file size shown.
If the file sizes do not match, delete the file without decompressing and then download the same file once again.
The required versions of software for this driver installer are as follows.
GP-Pro EX Ver. 2.10.000 or later
Pro-Server EX Ver. 1.30.000 or later You can check your version by "Help" function -> "Version Info".
Related Devices
MELSEC Q Series
MELSEC QnA Series
MELSEC L Series
MELSEC iQ-R Series
MELSEC iQ-F Series
Related Units
Required versions depend on models.
Please check "Supported Models / Version" for the required versions of GP-Pro EX.
Required driver versions for different models are listed below.
For details, please read the following
PDF: mit_qmc.pdf ( 2,730KB )
For general information regarding Device connection and documentation conventions, please refer to "Device/PLC Connection Manual".
Updated Contents
Ver. 1.15.06 (Dec. 8, 2016)
The following issue was fixed:
When using multiple CPUs, occasionally invalid values were read.
Occasionally normal communication was not possible when using Serial Multi Link.
Installation (This file is self-extracting.)
Please confirm that the supported software is installed in your computer. Prior to installing the driver, close all your personal computer applications, including any resident programs such as virus detection program, etc.
Click on the above file name to download the data to desired folder.
After the download to your PC is finished, double-click on the file's icon to start the installer program.
After the installer starts, follow the instructions given on each screen.
After installation, execute GP-Pro EX.
After installation, click on the Device/PLC area's [Mitsubishi Electric Corporation] selection and select [Q/QnA Serial Communication].
*
When using the driver, be sure to refer to the Device Connection Manual PDF (Shown above). Also, for general information regarding Device connection and documentation conventions please refer to "Device/PLC Connection Manual".
Update History:
[Ver. 1.15.06] (Dec. 8, 2016)
The following issue was fixed:
When using multiple CPUs, occasionally invalid values were read.
Occasionally normal communication was not possible when using Serial Multi Link.
[Ver. 1.15.05] (Oct. 17, 2016)
The following settings were added:
Multi CPU System is supported.
Added Related Device Series. MELSEC iQ-R Series, MELSEC iQ-F Series
[Ver. 1.14.05] (Dec. 12, 2014)
The following setting was added:
Added Related Device. Q03UDV CPU, Q04UDVCPU, Q06UDVCPU, Q13UDVCPU, Q26UDVCPU
The following issue was corrected:
When GP430 series and GP4000 series are mixed in the serial multilink, all GPs cannot make communications.
[Ver. 1.14.04] (Jul. 7, 2014)
The following setting was added:
LT3000 Series is supported.
[Ver. 1.13.04] (Mar. 29, 2010)
The following issue was corrected:
Using the Serial Multilink function, the display may not pass the token to other displays when the screen is changed.
[Ver. 1.13.03] (Oct. 5, 2009)
The following issues were corrected:
When not connecting via the Q Series C24 I/F Module, the ComErr lamp of the unit lights.
[Ver. 1.13.02] (Aug. 5, 2009)
The following settings were added:
Supported QnA Comp. 3C Frame: Format 4"
Supported Serial Multilink function
Added Related Device
Q00UJCPU/Q00UCPU/Q01UCPU/Q10UDHCPU/Q20UDHCPU/Q03UDECPU/Q04UDEHCPU/
Q06UDEHCPU/Q10UDEHCPU/Q13UDEHCPU/Q20UDEHCP/UQ26UDEHCPU
[Ver. 1.12.02] (Aug. 24, 2007)
The following settings were added:
Administration Bureau of MELSECNET and the master bureau of a remote IO net can be specified at the connection destination.
Last Updated : Dec. 8, 2016
Posted : Aug. 24, 2007