Products
Download
Contact us
Back to Top

Driver Download

PLCs >Mitsubishi Electric Corporation FX Series CPU Direct Driver

Please acknowledge the following terms of use before you use our download service. Download of any file signifies your agreement to the terms of use.

Terms of Use
  1. Schneider Electric Japan Holdings Ltd. ("SEJH") shall retain all intellectual property rights to the files that SEJH provides for this service.
  2. Who, uses or plans to use SEJH's products, may download and use any file.
  3. Reproduction, disclosure, re-publication, assignment, lease, decompilation, modification, falsification or reuse of any file that SEJH provides for this service shall be prohibited.
    However, for manuals, samples, BMP images and CAD files, you may reprint, duplicate, quote a part of the content or the whole on your company's specification sheets, or instruction manuals for built-in products. Also you may change the layout of the content.
  4. This download service is provided through the Internet. Please acknowledge that SEJH provides no guarantee of the condition at the time of provision, the availability of access and the condition of use concerning this service before you use this service.
  5. Please use this service at your own risk.
  6. If any additional conditions such as service usage conditions are attached to the downloaded files, please comply with such conditions as well.
Notices:
  1. Files are subject to deletion, or modification of the contents or specifications without notice.
  2. Please confirm that the downloading file size completely accords with the download file size shown.
  3. If the file sizes do not match, delete the file without decompressing and then download the same file once again.
 Download

Note:

Precautions for adding a new driver onto Windows Vista/7
Precautions for adding a new driver at Daylight Saving Time

Title Mitsubishi Electric Corporation FX Series CPU Direct Driver
Version Ver. 1.16.09
File Name MITFXCPU.exe
File Size 801KB
Applicable Software GP-Pro EX Ver. 2.10.000 or later
Pro-Server EX Ver. 1.30.000 or later
To check your version, go to the ” Help ” menu → ” Version Info ”.
Related Devices
  • MELSEC FX Series
Related Units
  • GP3000 Series
  • LT3000 Series
  • GP4100 Series (GP-4105, GP-4106: GP-Pro EX Ver. 2.60.000 or later, GP-4104 (Ethernet Multilink only): GP-Pro EX Ver. 2.70.000 or later.)
  • GP4000M Series (GP-Pro EX Ver. 2.71.000 or later)
  • GP4000 Series (GP-Pro EX Ver. 3.00.000 or later)
  • IPC Series for WinGP
  • General PCs for WinGP
Device/PLC Connection Manual For details, please read the following
PDF:mitfxcpu.pdf ( 888KB )

For general information regarding Device connection and documentation conventions, please refer to "Device/PLC Connection Manual".
Updated Contents Ver. 1.16.09 (Jan. 17, 2014)
The following setting was added:
  • FX3S Series is supported.

Installation (This file is self-extracting.)

  1. Please make sure that the supported software is installed. Prior to installion, close all applications running on a PC including any resident programs such as a virus detection program, etc.
  2. Click on the file name above to start downloading the file.
  3. After download is complete, double-click on the downloaded file to start installation.
  4. Follow the instructions on the screen.
  5. After installation, start GP-Pro EX/Pro-Server EX.
  6. Select [Mitsubishi Electric Corporation] for "Manufacturer" and [FX Series CPU Direct] for "Series" in [Device/PLC] settings of [System Settings] on the [Project] menu..
*
When using the driver, be sure to refer to the Device Connection Manual PDF (Shown above). Also, for general information regarding Device connection and documentation conventions please refer to "Device/PLC Connection Manual".

Update History:

[Ver. 1.16.09] (Jan. 17, 2014)

The following setting was added:
  • FX3S Series is supported.

[Ver. 1.15.09]

The following issue was corrected:
  • When the communication type settings for GP4201T and GP4301TM are different from those of the connected devices and further the time synchronization setting is specified, the screen may be locked during the startup.

[Ver. 1.15.08]

The following setting was added:
  • LT3000 Series is supported.

[Ver. 1.14.08]

The following setting was added:
  • GP4000 Series is supported.
    *GP-Pro EX Ver. 3.00.000 or later is necessary to use a GP4000 Series.
The following issue was corrected:
  • When "19200" is specified for Communication Speed in GP4100 series:
    Using the clock update function at the Display Unit's startup causes the communication error.

[Ver. 1.14.07]

The following settings were added:
  • GP4100 Series is supported.
    *GP-Pro EX Ver. 2.60.000 or later is necessary to use a GP4106 or GP4107
    *GP-Pro EX Ver. 2.70.000 or later is necessary to use a GP4104 (Ethernet Multilink).
  • GP4000M Series is supported.
    *To use GP4000M Series, GP-Pro EX Ver. 2.71.000 or later is required.

[Ver. 1.13.07] (Dec. 28, 2008)

The following setting was added:
  • FX3G Series is supported.

[Ver. 1.12.07] (Jun. 18, 2008)

The following issues were corrected:
  • When use Device Monitor, The address length error cannot be detected. The display doesn't change into "*".
  • When GP was powered ON. The SIO error is mis-detected.
  • When Flow Control is "NONE" GP cannot be communicated.
  • When PLC is reactivated while GP is communicating. GP cannot be communicated.
  • When connecting with FX1S, FX0N, FX0S and GP starts, the address length error is mis-detected.

[Ver. 1.12.06] (Nov. 5, 2007)

The following issue was corrected:
  • When connecting with FX3U, FX3UC and GP starts, the address length error is mis-detected.

[Ver. 1.12.05] (May. 31, 2007)

The following issues were corrected:
  • When communication is not established, an error is not displayed.
  • GP cannot communicate with FX1CPU.
The following setting was added:
  • Pass-through is supported.

[Ver. 1.11.04] (Jan. 9, 2007)

The following setting was added:
  • Support for Device Monitor
    *Ver. 2.00.000 or later version of GP-Pro EX are necessary to use a DeviceMonitor.

Last Updated : Jan 17, 2014
Posted : May 31, 2007

| Return to Top | | Back | HOME |
FAQ for use | Protection of Personal Information | Trademark Acknowledgments | About Intellectual Property Rights | Terms of Use
Copyright (C) 2005- Schneider Electric Japan Holdings Ltd. All Rights Reserved.