Products
Download
Contact us
Back to Top
 Driver Download
  > PLCs  > GE Intelligent Platforms Series 90-30 / 70 SNP driver

Please acknowledge the following terms of use before you use our download service. Download of any file signifies your agreement to the terms of use.

Terms of Use
  1. Schneider Electric Japan Holdings Ltd. ("SEJH") shall retain all intellectual property rights to the files that SEJH provides for this service.
  2. Who, uses or plans to use SEJH's products, may download and use any file.
  3. Reproduction, disclosure, re-publication, assignment, lease, decompilation, modification, falsification or reuse of any file that SEJH provides for this service shall be prohibited.
    However, for manuals, samples, BMP images and CAD files, you may reprint, duplicate, quote a part of the content or the whole on your company's specification sheets, or instruction manuals for built-in products. Also you may change the layout of the content.
  4. This download service is provided through the Internet. Please acknowledge that SEJH provides no guarantee of the condition at the time of provision, the availability of access and the condition of use concerning this service before you use this service.
  5. Please use this service at your own risk.
  6. If any additional conditions such as service usage conditions are attached to the downloaded files, please comply with such conditions as well.
Notices:
  1. Files are subject to deletion, or modification of the contents or specifications without notice.
  2. Please confirm that the downloading file size completely accords with the download file size shown.
  3. If the file sizes do not match, delete the file without decompressing and then download the same file once again.
 Download

Note:

Precautions for adding a new driver onto Windows Vista/7
Precautions for adding a new driver at Daylight Saving Time

Title GE Intelligent Platforms Series 90-30 / 70 SNP driver
Version Ver. 1.13.07
File Name GEF_SNP.exe
File Size 827KB
Applicable Software GP-Pro EX Ver. 1.00.003 or later
Pro-Server EX Ver. 1.00.000 or later
You can check your version by ” Help ” function→ ” Version Info ”.
Related Inverter

・Series 90-30
・Series 90-70

Related Units Required versions depend on models.
Please check "Supported Models / Version" for the required versions of GP-Pro EX. Required driver versions for different models are listed below.

Model Required driver version
GP3000 Series Ver. 1.10.01 or later
GP3000 Series
(Handy Type)
Ver. 1.11.02 or later
ST3000 Series Ver. 1.10.02 or later
GP4100 Series (GP4105, GP4106) Ver. 1.12.04 or later
GP4100 Series (GP4104: Ethernet Multilink only) Ver. 1.12.04 or later
GP4100 Series (GP4115, 4116) Ver. 1.13.06 or later
GP4100 Series (GP4114: Ethernet Multilink only) Ver. 1.13.06 or later
GP4000M Series Ver. 1.11.04 or later
GP4000 Series Ver. 1.11.04 or later
SP5000 Series Ver. 1.10.02 or later
IPC Series for WinGP Ver. 1.11.02 or later
General PCs for WinGP Ver. 1.11.02 or later
Device/PLC Connection Manual For details, please read the following
PDF: gef_snp.pdf ( 605KB )

For general information regarding Device connection and documentation conventions, please refer to "Device/PLC Connection Manual".
Updated Contents Ver. 1.13.07 (Jul. 5, 2018)
The following defect is fixed:
  • Communication errors sometimes were erroneously detected.

Installation (The downloaded file is self-extracting.)

1. Please confirm that the supported software is installed in your computer. Prior to installing the driver, close all your personal computer applications, including any resident programs such as virus detection program, etc.
2. Click on the above file "GEF_SNP.exe" to download the data to the desired folder.
3. After the download to your PC is finished, double-click on the file’s icon to start the installer program.
4. After the installer starts, follow the instructions given.
5.

After installation, execute GP-Pro EX.

6.

Click on the Device / PLC area’s [GE Intelligent Platforms] selection and select [Series 90-30 / 70 SNP].

*
When using the driver, be sure to refer to the Device Connection Manual PDF (Shown above). Also, for general information regarding Device connection and documentation conventions please refer to "Device/PLC Connection Manual".

Update history:

[Ver. 1.13.07] (Jul. 5, 2018)

The following defect is fixed:
  • Communication errors sometimes were erroneously detected.

[Ver. 1.13.06]

The following functionality was added:
  • SP5000 series are supported.
    * To use SP5000 Series, Ver. 4.00.000 or later of GP-Pro EX is necessary.

[Ver. 1.12.04]

The following functionality was added:
  • GP4100 (GP4105, 4106) are supported.
    * To use GP4100 Series, Ver. 2.60.000 or later of GP-Pro EX is necessary.

[Ver. 1.11.04]

The following functionality was added:
  • GP4000 Series is supported.
    * To use GP4000 Series, Ver. 3.00.000 or later of GP-Pro EX is necessary.

  • GP4000M Series is supported.
    * To use GP4000M Series, Ver. 3.00.000 or later of GP-Pro EX is necessary.

  • The manufacturer name was changed.

[Ver. 1.10.01] (Jul. 26, 2018)

New
 
Last Updated: Jul. 5, 2018
Posted: Jul. 26, 2006
 