Fieldbus/Other Devices
Fieldbus
Maker | Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, make sure to refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | LT 4000M | LT 3000 | PS4000 PL3000 PS3000 (WinGP) | Serial Multi Link | Sample | |
---|---|---|---|---|---|---|---|---|---|---|---|
CAN in Automation | - | - | - | ![]() |
- | - | - | - | - | - | |
CC-Link Partner Association |
CC-Link Intelligent Device
(MELSEC A, MELSEC QnA, MELSEC Q, MELSEC L) |
- | - | - | ![]() |
- | - | - | - | - | - |
ODVA (Open DeviceNet Vendor Association, Inc.) |
DeviceNet Slave
(SLC500, PLC-5, ControlLogix, MicroLogix, CompactLogix, SYSMAC α, SYSMAC CS1, SYSMAC CJ, S10mini, S10V, FA-M3) |
- | - | - | ![]() |
- | - | - | - | - | - |
PROFIBUS International |
PROFIBUS DP Slave
(SIMATIC S7-300/400, Other company devices which support PROFIBUS DP Master) |
- | - | - | ![]() |
- | - | - | - | - | ![]() |
- For further information, refer to "Device/PLC Connection Manual" after clicking each maker's name.
- The transfer driver's names with a symbol "★" requires to update a driver. Go to download page after clicking a Transfer Driver's name.
Other Devices
Maker Name | Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, make sure to refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | LT 4000M | LT 3000 | PS4000 PL3000 PS3000 (WinGP) |
Serial | |
---|---|---|---|---|---|---|---|---|---|---|
Azbil Corporation (formerly Yamatake Corporation) | Controller (CPL) Driver (Edge Measurement Sensor: PBC Series) (Gas Mass Flowmeter: CMS Series) (Medical Gas Mass Flowmeter: CMF Series) (Digital Mass Flow Controller: CMQ-V Series) (Panel Mount Mass Flow Controller: MPC Series) (Micro Flow Vortex Gas Flowmeter: MVF Series) (High-Flow Mass Flowmeter: CML Series) (Dynamic Self Check Burner Controller: AUR350C Series, AUR450C Series) (Burning Safety Control Device: RX Series) |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- | - |
Cognex Corporation |
In-Sight Vision Systems
(In-Sight 5000 Series Vision Systems, In-Sight Micro Vision Systems) |
![]() |
![]() |
- | ![]() |
![]() |
- | ![]() |
- | - |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- | - | ||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- | - | ||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- | - | ||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- | - | ||
Modbus-IDA |
General MODBUS RTU SIO Master
(MODBUS Compatible External Device) |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- | - |
General MODBUS TCP Master
(MODBUS Slave Device) |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- | - | |
ODVA (Open DeviceNet Vendor Association, Inc.) |
EtherNet/IP Explicit Messaging
(EtherNet/IP communication devices) |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- | - |
- For further information, refer to "Device/PLC Connection Manual" after clicking each maker's name.
- The transfer driver's names with a symbol "★" requires to update a driver. Go to download page after clicking a Transfer Driver's name.
- Only for GP3000 Series C Class (CANopen master supported display)
- CANopen Slave Unit (CA8-CANLT-01) is required.
- Not for GP-3200 Series and CANopen master supported display.
- Not for GP-3200 Series
- For 5.7 inch or larger Ethernet models with STN/TFT color LCD only. (For the GP-3300 Series, only units with Rev.4 or later are supported.)
- A driver for communication through a memory area in a main unit.
- A program driver for the send/receive command process by D script.
- Only for GP-4105/4106/4107
- Only for GP-4104
- When a logic executing time is long, the time to reply takes long. When time-out occurs to a Device/PLC of a master, make the time-out settings longer.